Codice d'errore caldaia RADIANT

16-12-2019 18:52

Peppe Morra (Moca clima)

CODICI D'ERRORE CALDAIE, CALDAIA RADIANT ERRORE E01 BLOCCO FIAMMA, CALDAIA RADIANT ERRORE E02, CALDAIA RADIANT ERRORE E03, CALDAIA RADIANT ERRORE E04, CALDAIA RADIANT ERRORE H20, CALDAIA RADIANT ERRORE E05, CALDAIA RADIANT ERRORE E06, CALDAIA RADIANT ERRORE E15, CALDAIA RADIANT ERRORE E16, CALDAIA RADIANT ERRORE E17, CALDAIA RADIANT ERRORE E18, caldaia radiant errore e21, caldaia radiant errore e22, caldaia radiant errore e35, caldaia radiant errore e40, caldaia radiant errore e77, caldaia radiant errore a01, caldaia radiant errore a02, caldaia radiant errore a03, caldaia radiant errore a04, caldaia radiant errore a06, caldaia radiant errore a14, caldaia radiant errore a16, caldaia radiant errore a17, caldaia radiant errore a18, caldaia radiant errore a20, caldaia radiant errore a35, caldaia radiant errore a39, caldaia radiant errore a40, caldaia radiant errore a51, caldaia radiant errore a80, caldaia radiant errore a81, caldaia radiant errore a83, caldaia radiant errore a84, caldaia radiant errore a85,

Codice d'errore caldaia RADIANT

in questo post trovi i codici d'errore x caldaie radiant

 

CODICI D’ERRORE CALDAIA RADIANT


E01 BLOCCO FIAMMA SENZA ACCENSIONE DI FIAMMA MANCANZA GAS; ELETTRODO DI ACCENSIONE ROTTO O A MASSA;VALVOLA GAS ROTTA;REGOLAZIONE MIN. MECCANICA(SULLA VALVOLA GAS) TROPPO BASSA O LENTA ACCENSIONE REGOLATE TROPPO BASSE; PRESSIONE IN ENTRATA VALVOLATROPPO ALTA (SOLO PER CALDAIEG.P.L.); CON ACCENSIONE DI FIAMMAALIMENTAZIONE ELETTRICAINVERTITA FASE E NEUTRO;ELETTRODO DI RIVELAZIONEROTTO;CAVO ELETTRODO DI RIVELAZIONESTACCATO;

VERIFICARE LA RETE DI ADDUZIONE;SOSTITUIRLO;SOSTITUIRLAREGOLAZIONE DELLA MINIMA O DELLA LENTAACCENSIONECONTROLLARE LA PREX. MASSIMA DI TARATURA;COLLEGARE CORRETTAMENTE LA CALDAIA;SOSTITUIRLO;COLLEGARE IL CAVO ELETTRODO DI RIVELAZIONE; leggi questo articolo ti potrebbe essere utile
 
E02 INTERVENTO DEL TERMOSTATO ALTA TEMPERATURA
TERMOSTATO ROTTO O STARATO, CONNESSIONE ELETTRICA STACCATA, O PIU' PROBABILMENTE HAI IL MINIMO DEL GAS TROPPO ALTO, OPPURE LO SCAMBIATORE PRIMARIO INTASATO
 
E03 PRESSOSTATO ARIA
PRESSO STATO ARIA ROTTO;SCARICO O ASPIRAZIONE CHIUSO;CAVO CONNESSIONE ELETTRICANON STABILE;
SOSTITUIRLO;VERIFICARE I CONDOTTI DELLO SCARICO FUMI;VERIFICARE LA CONNESSIONE ELETTRICA;
 
E04 / H2O MANCANZA DI ACQUANELL’IMPIANTO
PRESSIONE ACQUA NELL’IMPIANTOINSUFFICIENTE (STOP A 0.5 BAR);CAVO PRESSOSTATO ACQUASTACCATO;PRESSOSTATO ACQUA ROTTO;
CARICARE L’IMPIANTO;VERIFICARE IL COLLEGAMENTO ELETTRICO;SOSTITUIRLO;
 
E05 SONDA RISCALDAMENTO
SONDA ROTTA O STARATA (VALOREDI RESISTENZA 10KOHM A 25 °C)CONNETTORE SONDA STACCATO O BAGNATO;
SOSTITUIRLA;VERIFICARE LA CONNESSIONE ELETTRICA;
 
E06 SONDA SANITARIO
SONDA ROTTA O STARATA (VALOREDI RESISTENZA 10KOHM A 25 °C)CONNETTORE SONDA STACCATO O BAGNATO;
SOSTITUIRLA;VERIFICARE LA CONNESSIONE ELETTRICA;
 
E15 SONDA RITORNO   
SONDA ROTTA O STARATA (VALORE DI RESISTENZA 10 KOHM A 25 °C NTC);
CONNETTORE SONDA BAGNATO O SCOLLEGATO.
 
E16 ELETTROVENTILATORE
SCHEDA ELETTROVENTILATORE ROTTA/ELETTROVENTILATORE ROTTO
 
E17 MODULATORE GUASTO  MODULATORE VALVOLA GAS ROTTO - SOSTITUIRLOE22 RICHIESTA PROGRAMMAZIONEPARAMETRI
PERDITA DI MEMORIAMICROPROCESSORE RIPROGRAMMAZIONE
PARAMETRI;
 
E18 C I R C O L A Z I O N E INSUFFICENTE​
SCAMBIATORE OSTRUITO EFFETTUARE UNA PULIZIA DELLO SCAMBIATORE O SOSTITUIRLO:
CIRCOLATORE ROTTO O GIRANTE SPORCA.
 
E21 ERRORE GENERICO INTERNO SCHEDA
SHEDA MADRE COMPROMESSA E/O GUASTA
 
E 22 - RICHIESTA PROGRAMMAZIONE PARAMETRi
 
E31 CONTROLLORE REMOTO NON COMPATIBILE SEGNALA CHE IL CONTROLLORE REMOTO COLLEGATO ALLA CALDAIA NON È COMPATIBILE CON LA SCHEDA ELETTRONICA
 
E35 FIAMMA PARASSITA
ELETTRODO DI RILEVAZIONE FIAMMA MALFUNZIONANTE
 
E40  E77 TENSIONE DI ALIMENTAZIONE
TENSIONE DI ALIMENTAZIONE FUORI RANGE DI FUNZIONAMENTO (≤160/≥285 volts)VERIFICARE LA RETE DI ALIMENTAZIONEELETTRICA (L’ERRORE SI DISATTIVAAUTOMATICAMENTE NON APPENA LA TENSIONE DIALIMENTAZIONE RITORNA NEI LIMITI RICHIESTI)
 

E72 ERRORE CHECK UP PRESSOSTATO ARIA/ELETTROVENTILATORE

 

 

 

 

CALDAIA RADIANT R1HR 24 NOx :

 

A01 BLOCCO FIAMMA SENZA ACCENSIONE DI FIAMMA PREMERE IL TASTO RESET. leggi questo articolo ti potrebbe essere utile

 

A02 TERMOSTATO DI SICUREZZA (95°C) TERMOSTATO ROTTO O STARATO, CONNESSIONE ELETTRICA STACCATA, O PIU' PROBABILMENTE HAI IL MINIMO DEL GAS TROPPO ALTO, OPPURE LO SCAMBIATORE PRIMARIO INTASATO
 

A04 MANCANZA ACQUA NELL’IMPIANTO PRESSIONE ACQUA
 

A05 S O N D A RISCALDAMENTO SONDA ROTTA O STARATA (VALORE DI RESISTENZA 10 KOHM A 25 °C NTC);
 

A06 SONDA SANITARIO SONDA ROTTA O STARATA (VALORE DI RESISTENZA 10 KOHM A 25 °C NTC);
 

A14 LUNGHEZZA DEL CONDOTTO DI SCARICO FUMI NON CONFORME LA LUNGHEZZA DEL CONDOTTO DI SCARICO FUMI È SUPERIORE O MINORE A QUELLA RIPORTATA AL CAPITOLO ‘DATI TECNICI’.
 

A16 VALVOLA GAS DOPO LO SPEGNIMENTO DEL BRUCIATORE, IL SISTEMA CONTROLLA IL SEGNALE DI FIAMMA PARASSITA.

 

A17 MODULATORE MODULATORE VALVOLA GAS ROTTO


A18 C I R C O L A Z I O N E INSUFFICENTE
 

A20 AVVISO DI CATTIVA COMBUSTIONE A CALDAIA FUNZIONANTE CONDOTTO DI SCARICO/ASPIRAZIONE OSTRUITO VERIFICARE IL CONDOTTO DI SCARICO/ASPIRAZIONE . CLICCA QUI

 

A35 FIAMMA PARASSITA ELETTRODO MALFUNZIONANTE;
 

A39 SONDA ESTERNA SONDA ROTTA O STARATA
 

A40 TENSIONE DI ALIMENTAZIONE TENSIONE DI ALIMENTAZIONE , PROBABILE SCHEDA DANNEGGIATA
 

A51 AVVISO DI CATTIVA COMBUSTIONE IN FASE DI ACCENSIONE IN CASO DI SISTEMA FUMISTERIA SDOPPIATO,
I DIAFRAMMI NON SONO REGOLATI CORRETTAMENTE O LA MASSIMA VELOCITÀ DEL VENTILATORE NON
È STATA IMPOSTATA CORRETTAMENTE

 

A80 ELETTROVENTILATORE ERRATA CONNESSIONE DELL’ELETTROVENTILATORE
 

A81 PERDITA DI FIAMMA LA FIAMMA È SCOMPARSA PER 6 VOLTE NELL’ARCO DI 10 MINUTI. LEGGI
 

A83 ANOMALIA A20 CHE SI VERIFICA 6 VOLTE IN 10 MINUTI 

 

A84 VALVOLA GAS CAVO VALVOLA GAS SCOLLEGATO O ROTTO
 

A85 AVVISO DI SOVR ATEMPERATURA TRAMITE SONDA RISCALDAMENTO
 